<img height="1" width="1" src="https://www.facebook.com/tr?id=1582471781774081&amp;ev=PageView &amp;noscript=1">
 

Cytokine and Chemokine Profiling Services

 Quantify immune signaling proteins across species and matrices, from single-analyte ELISA to 100+ plex multiplex panels, to characterize mechanism of action, immunogenicity, and toxicity risk. 

Maximize Therapeutic Effect and Limit Toxicities through Cytokine and Chemokine Profiling

Determining whether a new therapeutic drives the right immune response or triggers toxic cytokine release is difficult, particularly when single-analyte testing consumes sample volume one protein at a time.

Our Crown Bioscience cytokine and chemokine profiling platform combines ELISA with multi-analyte Luminex® and MSD® S600 technologies, allowing us to quantify multiple cytokines and chemokines from a single sample and deliver mechanism-of-action and toxicity insights in one run. We measure the secreted signaling proteins that coordinate the immune response, including interleukins, interferons, chemokines, and growth factors, in serum, plasma, tissue lysate, or cell culture supernatant. With assays ranging from a single analyte to more than 100 analytes per sample, our profiling supports mechanism-of-action studies, immunogenicity assessment, and safety and toxicity biomarker discovery for oncology and immuno-oncology programs. 

Why Profile Cytokines and Chemokines 

Cytokine and chemokine profiling data lets your team:

  • Characterize mechanism of action by measuring the in vitro cytokine/chemokine response your agent induces in target cell populations
  • Predict and monitor immunogenicity by tracking cytokine release in vivo following dosing
  • Flag toxicity risk early by identifying cytokine release syndrome (CRS) signatures and other inflammatory signals before they surface in the clinic
  • Discover and qualify candidate biomarkers for treatment response or adverse event prediction, feeding directly into your broader biomarker discovery strategy

Applications

  • Mechanism of action confirmation- measure the in vitro cytokine/chemokine response your agent induces to confirm target engagement and immune activation

  • Immunogenicity and toxicity risk assessment- detect in vivo cytokine release that may signal adverse events before they escalate

  • Biomarker discovery- identify candidate cytokines and chemokines that predict response or toxicity, supporting patient stratification strategies downstream

  • High-throughput multi-analyte screening- quantify dozens of targets simultaneously across Luminex® and MSD S600 platforms, in addition to conventional single-plex ELISA

Detect and Quantify Cytokines and Chemokines in High Throughput with our Multi-Analyte Profiling Platform

Alongside conventional single plex ELISA you can also utilize multi-analyte profiling via Luminex® and MSD S600, enabling you to:

  • Rapidly quantify multiple proteins simultaneously
  • Reduce workflow and sample volume requirements by combining assays for multiple target analytes in a single reaction volume
  • Quantify targets at radically different concentrations by providing linearity over a wide range

cytokine-and-chemokine-profiling-1x

Figure 1 Cytokine Detection in Naïve MC38 Tumors Grown in Humanized Genetically Modified Mouse Models

 

Validated Panels Available

Mouse Cytokine/Chemokine Universal Panel (32-plex): G-CSF, GM-CSF, IFN-γ, IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-9, IL-10, IL-12(p40), IL-12(p70), IL-13, IL-15, IL-17, IP-10, KC, LIF, LIX, MCP-1, M-CSF, MIG, MIP-1α, MIP-1β, MIP-2, RANTES, TNF-α, VEGF, Eotaxin/CCL11

Mouse TH17 Panel: CD40 Ligand, GM-CSF, IFN-γ, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-10, IL-12(p70), IL-13, IL-15, IL-17A, IL-17E/IL-25, IL-17F, IL-21, IL-22, IL-23, IL-27, IL-28B, IL-31, IL-33, MIP-3α/CCL20, TNF-α, TNF-β

MSD V-PLEX Human Proinflammatory Panel: IFN-γ, IL-1β, IL-6, TNF-α (4-plex), with expanded 10-plex option

MSD V-PLEX Human Chemokine Panel: MCP-1, MCP-4, Eotaxin, Eotaxin-3, IP-10, MDC, TARC, MIP-1α, MIP-1β, IL-8

 

How It Works

  • Consult — Share your study design, species, target analytes, and sample type; we recommend the platform and panel that fits your throughput, sensitivity, and budget needs
  • Profile — Samples are run on validated ELISA, Luminex, or MSD platforms with appropriate QC/QA controls
  • Report — Receive quantitative data (concentration + QC metrics), with bioinformatics interpretation available for panel-level and pathway-level analysis
  • Integrate — Cytokine/chemokine data can be layered with Crown Bioscience's in vivo humanized and syngeneic models, flow cytometry, and immune monitoring services for a complete immune response picture

Why Crown Bioscience 

  • Global lab network with integrated oncology and immuno-oncology model systems — cytokine data generated alongside PDX, syngeneic, and humanized mouse studies, not in isolation
  • Platform flexibility (ELISA, Luminex, MSD, ELISpot) matched to your analyte count, sensitivity needs, and sample volume constraints
  • Deep bench in immuno-oncology biomarker strategy, from discovery through translational and clinical biomarker services

Frequently Asked Questions

What's the difference between cytokine and chemokine profiling?

Cytokines are a broad category of signaling proteins that regulate immune and inflammatory responses, including interleukins, interferons, and growth factors. Chemokines are a subset of cytokines that specifically direct cell migration (chemotaxis). Profiling typically measures both categories together in a single multiplex panel since they act within the same signaling networks.

Luminex vs. MSD: which platform should I use?

 Luminex xMAP is best for high-plex screening (up to 100+ analytes) where broad coverage and sample-volume efficiency matter most. MSD's electrochemiluminescence technology offers greater sensitivity for low-abundance analytes in complex matrices like CSF or tissue lysate. Many programs screen broadly on Luminex first, then confirm low-abundance hits on MSD. 

How much sample volume is needed for multiplex cytokine profiling?

 Multiplex platforms like Luminex typically require 25–50 µL per sample to quantify dozens of analytes simultaneously, versus running each analyte separately by ELISA, which would require proportionally more volume per analyte. This makes multiplexing the preferred approach when working with limited clinical or in vivo samples. 

When should cytokine and chemokine profiling be performed during drug discovery?

 Cytokine and chemokine profiling can provide valuable insights throughout drug discovery, including target validation, lead optimization, preclinical efficacy studies, PK/PD investigations, toxicology assessments, and translational biomarker development. Measuring soluble immune mediators at multiple study timepoints helps researchers understand pharmacodynamic responses, characterize mechanism of action, monitor immune activation, and identify biomarkers that may support future clinical studies. 

Can cytokine profiling help identify pharmacodynamic biomarkers?

 Yes. Changes in cytokine and chemokine expression often serve as sensitive pharmacodynamic biomarkers that demonstrate biological activity following treatment. These biomarkers can support mechanism-of-action studies, dose selection, therapeutic optimization, and translational research by linking immune responses with efficacy outcomes. 

Can cytokine profiling predict immune-related toxicity?

 Cytokine profiling is commonly incorporated into preclinical safety studies to monitor immune activation associated with therapeutic candidates. Measuring cytokine responses may help identify biomarkers associated with excessive immune stimulation, cytokine release, or other immune-mediated toxicities, allowing researchers to make more informed development decisions. 

Can cytokine profiling be integrated with other biomarker analyses?

Yes. Cytokine and chemokine profiling is frequently combined with complementary biomarker technologies including:

  • Flow cytometry
  • Digital pathology
  • Immunohistochemistry (IHC)
  • Discovery proteomics
  • Transcriptomics
  • Spatial biology
  • Bioinformatics and multiomics analysis

Integrating multiple biomarker modalities provides a more comprehensive understanding of immune responses and therapeutic mechanisms.

Can Crown Bioscience customize cytokine panels?

 Yes. In addition to standard cytokine panels, Crown Bioscience works with sponsors to develop customized analyte panels tailored to therapeutic area, disease biology, and study objectives. Custom panel design helps ensure the most biologically relevant biomarkers are measured for your program. 

What therapeutic areas benefit from cytokine and chemokine profiling?

Cytokine profiling is widely used across:

  • Oncology
  • Immuno-oncology
  • Autoimmune disease
  • Inflammatory disorders
  • Infectious disease
  • Cell and gene therapy
  • Vaccine development

The data generated can help evaluate immune activation, treatment response, immunogenicity, and potential toxicity.

Discuss Your Cytokine and Chemokine Profiling Project